NYMC Faculty Publications
Development of a Multiantigen Panel for Improved Detection of Borrelia Burgdorferi Infection in Early Lyme Disease
Author Type(s)
Faculty
DOI
10.1128/JCM.02111-15
Journal Title
Journal of Clinical Microbiology
First Page
3834
Last Page
3841
Document Type
Article
Publication Date
12-1-2015
Department
Pathology, Microbiology and Immunology
Keywords
Adult, Aged, Antibodies, Bacterial, Antigens, Bacterial, Borrelia burgdorferi, Cohort Studies, Diagnostic Tests, Routine, Early Diagnosis, Female, Humans, Immunoassay, Immunoglobulin G, Immunoglobulin M, Lyme Disease, Male, Membrane Proteins, Middle Aged, Sensitivity and Specificity, United States, Young Adult
Disciplines
Medicine and Health Sciences
Abstract
The current standard for laboratory diagnosis of Lyme disease in the United States is serologic detection of antibodies against Borrelia burgdorferi. The Centers for Disease Control and Prevention recommends a two-tiered testing algorithm; however, this scheme has limited sensitivity for detecting early Lyme disease. Thus, there is a need to improve diagnostics for Lyme disease at the early stage, when antibiotic treatment is highly efficacious. We examined novel and established antigen markers to develop a multiplex panel that identifies early infection using the combined sensitivity of multiple markers while simultaneously maintaining high specificity by requiring positive results for two markers to designate a positive test. Ten markers were selected from our initial analysis of 62 B. burgdorferi surface proteins and synthetic peptides by assessing binding of IgG and IgM to each in a training set of Lyme disease patient samples and controls. In a validation set, this 10-antigen panel identified a higher proportion of early-Lyme-disease patients as positive at the baseline or posttreatment visit than two-tiered testing (87.5% and 67.5%, respectively; P < 0.05). Equivalent specificities of 100% were observed in 26 healthy controls. Upon further analysis, positivity on the novel 10-antigen panel was associated with longer illness duration and multiple erythema migrans. The improved sensitivity and comparable specificity of our 10-antigen panel compared to two-tiered testing in detecting early B. burgdorferi infection indicates that multiplex analysis, featuring the next generation of markers, could advance diagnostic technology to better aid clinicians in diagnosing and treating early Lyme disease.
Recommended Citation
Lahey, L. J., Panas, M. W., Mao, R., Delanoy, M., Flanagan, J. J., Binder, S. R., Rebman, A. W., Montoya, J. G., Soloski, M. J., Steere, A. C., Dattwyler, R. J., Arnaboldi, P. M., Aucott, J. N., & Robinson, W. H. (2015). Development of a Multiantigen Panel for Improved Detection of Borrelia Burgdorferi Infection in Early Lyme Disease. Journal of Clinical Microbiology, 53 (12), 3834-3841. https://doi.org/10.1128/JCM.02111-15
