The Intra-Articular Tendinous Graft Diameter of 10-Mm Bone-Patellar Tendon-Bone Autografts in Adolescent Patients: An MRI Analysis of 100 Patients

Author Type(s)

Student

Document Type

Article

Publication Date

8-1-2024

DOI

10.1177/23259671241264503

Journal Title

Orthopaedic Journal of Sports Medicine

Abstract

BACKGROUND: Bone-patellar tendon-bone (BPTB) autograft size may be one modifiable predictor of anterior cruciate ligament (ACL) reconstruction postoperative success, as smaller graft diameter has been associated with higher rates of rupture requiring revision. However, measuring the true intra-articular tendinous graft diameter of the soft tissue portion of a BPTB graft with standard intraoperative methods is difficult while keeping the graft intact.

PURPOSE/HYPOTHESIS: The purpose of the study was to use 3-dimensional magnetic resonance imaging (MRI) measurements to determine the cross-sectional area of the soft tissue, tendinous portion of a standard BPTB autograft with 10-mm diameter bone plugs, and, by calculation, the collagen graft size (ie, graft diameter), as would typically be reported in ACL reconstruction studies that consider soft tissue graft size. It was hypothesized that the calculated collagen graft diameter of 10-mm BPTB autografts would be significantly smaller than 10 mm.

STUDY DESIGN: Cross-sectional study; Level of evidence, 3.

METHODS: A total of 100 patients (10 girls and 10 boys at each age from 13 to 17 years) who underwent a knee MRI at a single academic orthopaedic center without documented extensor mechanism pathology were identified. The central 10-mm width of the patellar tendon that would be harvested for BPTB autograft was measured. The region of interest area tool was then used to measure the cross-sectional area of a 10-mm BPTB graft with subsequent soft tissue autograft diameter calculation.

RESULTS: The mean calculated tendinous graft diameter of a 10 mm-wide BPTB graft was 6.3 ± 0.5 mm and was significantly smaller than a 10-mm reference (

CONCLUSION: Modern 3-dimensional imaging-based measurement techniques demonstrated that the true intra-articular tendinous soft tissue portion of 10-mm BPTB autografts shows substantial variation and is significantly smaller in diameter than the tunnels typically reamed to accommodate the bone plug portions of these grafts. Moreover, as graft size is a predictor of rupture rate, preoperative MRI-based evaluation may be an important tool when considering BPTB autograft for ACL reconstruction. Future comparative clinical research utilizing graft size as a study variable should consider quantifying and utilizing the diameter of the soft tissue component of BPTB autografts.

Share

COinS